Chromatography systems facilitate the molecular separation of sample mixtures needed for closer analysis. This equipment is used heavily in research and clinical laboratories for the rapid processing and precise retention time recordings. The chromatography systems may be selected to fit specific testing methods. For the very best results, consider the sample nature and desired outcome when choosing the most ideal machine and solvent. Reduced start up times and advanced technology may vary among models.

Chromatography systems facilitate the molecular separation of sample mixtures needed for closer analysis. This equipment is used heavily in research and clinical laboratories for the rapid processing and precise retention time recordings. The chromatography systems may be selected to fit specific testing methods. For the very best results, consider the sample nature and desired outcome when choosing the most ideal machine and solvent. Reduced start up times and advanced technology may vary among models.


65  results were found

Sort Results

List View Easy View (new)
SearchResultCount:"65"
Description: Chromaster HPLC 5450 refractive index detector, With short stabilisation time and flow cell with variable temperature setting. Refractive index range: 1 - 1,75
Catalog Number: 903-0528
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster HPLC 5420 UV/Vis variable wavelength detector, Low noise and low drift for high sensitivity detection with two-wavelength simultaneous measurement function. Automatic wavelength accuracy check with Hg lamp. D₂ lamp and W lamp combined wavelength range: 190 - 900 nm. Supplied with 13 µl cell, 10 mm path length. Other flow cell options available
Catalog Number: 903-0525
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5110 pump with auto-purge valve, 400 bar max. operating pressure (9,99 ml/min max. flow rate), Pumping system: Dual plunger reciprocating pump system; Series connection, pulsation elimination system
Catalog Number: 903-0501
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5110 pump with manual purge valve, 400 bar max. operating pressure (9,99 ml/min max. flow rate), Pumping system: Dual plunger reciprocating pump system; Series connection, pulsation elimination system
Catalog Number: 903-0500
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus organiser for solvent placement and power supply, Space for 5 x 1,0 l bottles and 2 x 500 ml bottles
Catalog Number: 903-0537
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5280 autosampler with 100 µl syringe. 600 bar max. operating pressure, ≤0,003% RSD specified carry over. Direct injection with needle integrated into sample loop for low sample volumes. Wash solvent delivery by syringe. 200 x 1,5 ml vial rack included. Other rack options available
Catalog Number: 903-0344
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5280 autosampler with Peltier cooling unit and 100 µl syringe. 600 bar max. operating pressure, ≤0,003% RSD specified carry over. Direct injection with needle integrated into sample loop for low sample volumes. Temperature setting range: 4 to 35 °C. Wash solvent delivery by syringe. 200 x 1,5 ml vial rack included. Other rack options available
Catalog Number: 903-0345
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster HPLC 5440 fluorescence detector, With variable spectral bandwidth. Xenon lamp included. Automatic wavelength accuracy check with Hg lamp. Flow cell with 12 µl irradiation volume included. Other flow cell options available
Catalog Number: 903-0164
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster HPLC 5430 flow cell
Catalog Number: 903-0320
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster HPLC 5430 diode array detector without flow cell, 1,024 bit PDA. Excellent baseline stability, low drift and low noise. 100 Hz max data acquisition rate. Automatic wavelength accuracy check with Hg lamp. Wavelength range: 190 - 900 nm. Semi-micro, standard, thermostatted and semi-preperative flow cells available
Catalog Number: 903-0597
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM6310 - column oven for max. 6×150 mm columns or max. 3×300 mm columns, Temperature range 4 to 90 °C with fast heating and cooling block. 1 µl preheater. Optional switching valves available. Column management system option available
Catalog Number: 903-0361
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus Basic UV CSA5HE package including CM5160 pump with manual purge valve, 600 bar, low pressure quaternary gradient unit, 6-channel degassing unit, CM5260 autosampler, CM5310 column oven, CM5410 UV detector, organiser, interface control board, ChromSwordAuto® 5 Hitachi Edition including CDS and Scout System, VWR®/Hitachi starter kit
Catalog Number: 903-0370
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC complete 600 bar system for standard bore columns with CM5160 manual purge quaternary gradient pump, CM5260 thermostat standard loop autosampler, CM5310 column oven, CM5430 diode array detector, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5260 autosampler with low carry-over loop injection, 175 µl syringe 120 vial peltier thermostatted rack from 1 to 45 °C and dual needle and port washing system. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. 5430 diode array detector with 1.024 bit PDA, auto wavelength check, range 190 - 900 mm with 13 µl, 10 mm cell. All cables and interface board included
Catalog Number: 903-0355
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial rack and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 to 85 °C. All cables and interface board included
Catalog Number: 903-0359
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC base 600 bar system with CM5160 manual purge quaternary gradient pump, CM5280 thermostat direct injection autosampler, CM5310 column oven, 5160 low pressure gradient pump with 6 channel degasser, max. flow rate of 4,99 ml/min. Dual plunger reciprocating pump system; Series connection, pulsation elimination system. 5280 autosampler with 200 vial peltier rack, 4 to 35 °C, and direct injection with needle integrated into sample loop, 100 µl syringe for accurate sample metering. 5310 oven with peltier block and air circulation for max. 3 x 300 mm columns, temperature set range: 1 °C to 85 °C. All cables and interface board included
Catalog Number: 903-0358
UOM: 1 * 1 items
Supplier: VWR Collection


Description: Chromaster Plus HPLC CM5310 Advanced Spec - column oven for max, 3×300 mm columns, Temperature range 1 to 85 °C peltier heating and cooling block for excellent stability. Optional switching valves available. Column management system option available
Catalog Number: 903-0520
UOM: 1 * 1 items
Supplier: VWR Collection