You Searched For: Electrophoresis+Sequencers


13 215  results were found

SearchResultCount:"13215"

Sort Results

List View Easy View (new)

Rate These Search Results

Catalog Number: (K872-500ML)
Supplier: VWR Chemicals
Description: For transfer of protein to membranes for sequencing or blotting.
UOM: 1 * 500 mL

MSDS


Catalog Number: (K656-500ML)
Supplier: VWR Chemicals
Description: A.C.E.™ Sequencing Buffers are optimised buffers for DNA capillary electrophoresis sequencing that provide excellent results like long read lengths, high resolution, and consistent run times.
UOM: 1 * 500 mL

MSDS


Why would you use an automatic colony counter?

Our VWR® colony counters range from low-cost units for quick counts to high-end models for extended applications and IQ/OQ

WATCH THE VIDEO

Consistency-Accuracy-Speed-Efficiency

C.A.S.E.
Supplier: VWR Chemicals
Description: Commonly used to denature nucleic acids for electrophoresis and to study the secondary and tertiary structure of proteins. Effective for maintaining DNA in a highly denatured state during sequencing protocols.
Catalog Number: (ENZOENZ40849)
Supplier: ENZO LIFE SCIENCES
Description: The Blur 8 BioProbe® labeled probe is prepared by nick translation of a clone of the human alu repeat sequence. Fragment size range: 100-1000 base pairs (as estimated by agarose gel electrophoresis).
UOM: 1 * 2 µG

New Product


Catalog Number: (M124-250ML)
Supplier: VWR Chemicals
Description: A convenient pre-mixed solution that is easily diluted for buffer preparation under denaturing conditions.Commonly used to denature nucleic acids for electrophoresis and to study the secondary and tertiary structure of proteins. Effective for maintaining DNA in a highly denatured state during sequencing protocols, urea is also useful for accelerating the activity of Proteinase K digestions.
UOM: 1 * 250 mL

Catalog Number: (ENZOENZ40834)
Supplier: ENZO LIFE SCIENCES
Description: The Adenovirus BioProbe® labeled probe is prepared by nick translation of cloned fragments of the adenovirus 5 genome. The fragments constitute a total of 20 kb of DNA, approximately 56% of the genome. The probe is specific for adenovirus and, in addition to hybridization to adenovirus 5 sequences, the probe will cross hybridize with adenovirus types 4, 7, 11, 20, 40 and 41 due to their considerable sequence homology. Fragment size range: 100-1000 base pairs (as estimated by agarose gel electrophoresis).
UOM: 1 * 2 µG

New Product


Catalog Number: (ROCKMB-045)
Supplier: Rockland Immunochemicals
Description: Saline-sodium citrate (SSC) buffer is most commonly used as a buffer for the hybridisation process and washing in experiments where spcies of nucleic or ribonucleic acid are to be matched to complimentary sequences (such as Southern and Nouthern blotting, <i>in situ</i> hybridisation, or DNA microarrays). SSC is used to help control the stringency of hybridisation in these steps.
UOM: 1 * 1 L


Supplier: THERMO OWL SCIENTIFIC
Description: Electrophoresis sequencer, accessories

Catalog Number: (OWLAS4S)
Supplier: THERMO OWL SCIENTIFIC
Description: Electrophoresis sequencer, Owl™ S4S sequencer, 45×20 cm
UOM: 1 * 1 items


Supplier: OWL SCIENTIFIC
Description: Accessories for sequencers, aluminium-backed, Owl™

Supplier: G-Biosciences
Description: GELPLATE-clean™ removes proteins, nucleic acids, fats, lipids, radioisotopes and other contaminants from electrophoresis gel plates. It is suitable for sequencing and protein electrophoresis gel plates.

Supplier: AGILENT
Description: DNA analysis for large smears, fragment sizing, long read NGS library QC and single molecule sequencing.

Catalog Number: (730-1529)
Supplier: CONSORT
Description: A complete range of power supplies for electrophoresis applications, including DNA sequencing, flat bed iso-electric focussing, horizontal and vertical gels, electro-elution, Western blotting and semi-dry blotting.
UOM: 1 * 1 items


Catalog Number: (GREI770280_960)
Supplier: Greiner Bio-One
Description: These gel loading tips are characterised by an elongated end. They are ideal for numerous molecular biological applications, especially for filling the slots of sequencing, PCR and protein electrophoresis gels.
UOM: 1 * 960 items


Catalog Number: (27-2090-02)
Supplier: Cytiva
Description: Band compressions are ambiguous band patterns on sequencing gels caused by stable intra-strand secondary structures that are not fully denatured during electrophoresis. Their occurrence can be reduced by substituting nucleotide analogues in the sequencing mixes. 7-Deaza dGTP (c⁷dGTP) can be used to resolve G-band compressions.
UOM: 1 * 2 µmol


Catalog Number: (BE-409)
Supplier: G-Biosciences
Description: In this lab activity, students learn to perform carefully controlled experiments to generate protein fragments using a proteolysis enzyme and then analyse the protein fragments by electrophoresis. By analysis of protein fragmentation patterns, i.e. protein fingerprints, students learn about protein sequence, structure, and their conservation. Students resolve a set of three functionally identical protein samples selected from throughout the animal kingdom; including human, bovine and sheep. After generating fingerprints by electrophoresis, students examine the protein fingerprint of each sample to determine the degree of conservation.
UOM: 1 * 1 KIT


Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at +43 1 97002 - 0.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at +43 1 97002 - 0.
Dual use goods can only be delivered within the European Union.
Dual use goods can only be delivered within the European Union.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
This product is no longer available. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service at +43 1 97002 - 0.
1 - 16 of 13 215
no targeter for Bottom